The Facility and Energy Management Project Team is responsible for the planning and designing of data objects for energy usage
The Facility and Energy Management objects are used to report energy usage and associated environmental information; and to convey the results of the analysis of that information in standardized reports. The Energy Usage Object provides multiple information sources with the opportunity to publish time-based events containing Energy Usage data for a school building or facility. This information includes:
The primary goal of this object is to allow maximum flexibility in the ways in which a SIF Zone may be utilized to gather energy management data published by multiple sources, while leaving it to the Energy Analysis program (the subscriber) to take the varied data events issued in conformance with this SIF standard, and correlate them into a unified format which it can use. In general this will involve storing the information in the equivalent of an Energy Management longitudinal data system (LDS).
Please see Appendix E: Energy Management Notes for more detail about this object.
Element/@Attribute | Char | CEDS Id/URL | Description | Type | |
---|---|---|---|---|---|
EnergyUsage | This object contains energy usage information for an energy location. | ||||
@ | RefId | M | A GUID that identifies an instance of this object. This RefId is a “transient” value; that is, it SHOULD be generated by the provider at the time the object is provided in a Response message. This value MUST NOT be used in a later Request for the object. | RefIdType | |
UsageLocationInfo | M | Complex element containing the location of where measurements apply to. | EnergyUsageLocationInfoType | ||
DataSource | O | The description of the source of the measurements. | EnergyUsageDataSourceType | ||
SIF_Metadata | O | SIF_MetadataType | |||
SIF_ExtendedElements | O | SIF_ExtendedElementsType |